Health And YogaYogaYoga Community- Teacher, Jobs & ToolsYoga Products - Yoga Mats, Yoga VideosYoga Retreats & HolidaysYoga Reading, Yoga Articles, Yoga Books..Yoga Teacher Training Worldwide
Physiology of Meditation Techniques   |   Physiology of Pranayama   |   Yoga For Rehabilitation   |   Yoga in Perception and Performance   |   Therapeutic Applications of Yoga

 
Oxygen Consumption During Pranayamic Type Slow-Rate Breathing
 
Alterations of AEPs During Yogic Breathing and Attentive State if Mind
 
Breathing Through a Nostril can alter Metabolism and Autonomic Activities
 
Physiological Measures of Right Nostril Breathing
 
Effect Two Yogic Breathing Techniques on Heart Rate Variability
 
Recording of the Endosomatic Sympathetic Skin Response
 
Letter 1
 
Letter 2
 
Letter 3
 
Letter 4
 
Letter 5

AMPLIFIER SETTINGS AND THE RECORDING OF THE  ENDOSOMATIC SYMPATHETIC SKIN RESPONSE

N. Ravi, H.R. Nagendra & Shirley Telles 

Vivekananda Kendra Yoga Research Foundation, Bangalore, India.
 

Abstract : The sympathetic skin response (SSR) is a measure of the electrodermal activity recorded by an endosomatic method, i.e., without using external current. It correlates with exogenous (e.g., a sound) and endogenous (e.g., a deep breath) stimuli. This paper describes the variations in the SSR waveform with varied amplifier filter settings (low cut filter settings 0.1 Hz, 0.3 Hz, and 5.0 Hz and high cut filter settings 15 HZ, 35 Hz, and 75 Hz) in 25 healthy male volunteers (aged between 20 and 40 years); under different physiological conditions (e.g., deep breathing and with successive sound stimuli). The optimal amplifier settings for psychophysiological studies using the SSR are discussed.
 

INTRODUCTION
Introduction The sympathetic skin response (SSR) is a slow wave, generated in deep layers of the skin, resulting from reflex activation of the sudomotor sympathetic efferent fibers. This slow galvanic reflex response is known to occur following a deep breath, an unexpected or arousing stimulus [1]. Its possible clinical uses in the diagnosis of autonomic disorders in both central and peripheral neuropathies, is gaining importance. As the spontaneous response and that to endogenous stimuli is a relatively new, inadequately worked out parameter in neurological studies, the amplifier filter settings for optimal recording were evaluated in the present study. 

The component in equipment that eliminates unwanted frequencies is a filter [2]. A high frequency filter will affect the designated frequency by 20 or 30 percent and is expected to affect frequencies slower than the designated at a progressively lesser degree until there is no attenuation at all. In contrast frequencies above the designated filter will have progressively more than 20 or 30 percent attenuation so that in all cases some higher frequencies will be attenuated and be eliminated.

 


Fig.1 Calibration


The terms time constant and low linear frequency are used interchangeably in considering the effect on slow activity, but the number is not the same where the terms are varied. A time constant of 1 sec represents a low linear frequency filter of 0.1 Hz. It is understood that the low frequency filter attenuates rather than eliminates low frequencies.

The present study assessed the SSR in normal volunteers during baseline conditions, while breathing deeply, and when given auditory stimuli. The filter settings were varied and the optimal SSR, with respect to number of responses and maximum amplitude was determined.

All Research Papers are published online courtesy www.vyasa.org
 

You do not have permission to sell or distribute or reproduce Health and Yoga ResearchPapers text or any portion of the text in any form (printed, electronic or otherwise). To do so is a violation of copyright law
Read More...

Research Contributions of
SVYASA
(2 Volumes)
PRINT EDITION
US $ 33.00
Click here to Buy


Apply for
PhD
at
VYASA
Click here